BJNBB - FLAW-FINDER AG-RH CLEANER (POST 3/90)
- MSDS: BJNBB
- Manufacturer: AMERICAN GAS AND CHEMICAL COMPANY LTD
- Product Name: FLAW-FINDER AG-RH CLEANER (POST 3/90)
- National Stock Number: 6850-00-826-0981
Product Identification
Product ID:FLAW-FINDER AG-RH CLEANER (POST 3/90)
MSDS Date:03/30/1990
FSC:6850
NIIN:00-826-0981
Kit Part:Y
MSDS Number: BJNBB
Responsible Party
NORTHVALE, NJ 07647-1904
US
Emergency Phone: 201-767-7300
Info Phone: 201-767-7300
Preparer: GEORGE KOSEL,CHIEF CHEM
Cage: 03530
Contractor
Telephone: 201-767-7300
Cage: 03530
Ingredients
METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 96.0%
OSHA PEL 350 PPM/450 STEL
ACGIH TLV: 350 PPM/450STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CHLORODIFLUOROMETHANE
CAS: 75-45-6
RTECS: PA6390000
Fraction By Weight: 4.0%
OSHA PEL 1000 PPM
ACGIH TLV: 1000PPM; 9192
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRITATION OF EYES, SKIN,
RESPIRATORY TRACT; HEADACHE, DIZZINESS, ANESTHETIC EFFECTS, CNS
DEPRESSION; CHRONIC: DEFATTING, DERMATITIS; HEALTH STUDIES HAVE
SHOWN THAT MANY HALOGENATED HYDROCARBON S POSE POTENTIAL HUMAN
HEALTH RISKS WHICH MAY VARY FROM PERSON TO PERSON.
Explanation of Carcinogenicity:MFRG STATED THAT 1,1,1-TRICHLOROETHANE
HAS BEEN SUBJECTED TO A CARCINOGENESIS BIOASSAY BY NCI AND FOUND
NOT A CARCINOGEN
Effects of Overexposure:INHALATION:HIGH VAPOR CONC CAUSES
IRRITATION,HEADACHE,DIZZINESS AND CNS
DEPRESSION;SKIN:PROLONGED/REPEATED CONTACT TENDS TO REMOVE SKIN OIL
POSSIBLY LEADING TO IRRITATION AND DERMATITIS;EYES:LIQ CONTA CT MAY
CAUSE IRRITATION;INGESTION:PRODUCT HAS LOW ORDER OF ACUTE ORAL
TOXICITY.MINUTE QTY INSPIRATED IN LUNGS IS FATAL.
Medical Cond Aggravated by Exposure:NONE REPORTED BY THE MANUFACTURER.
HOWEVER, PRE-EXISTING CONDITIONS MAY BE WORSEN.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR: SEEK MEDICAL HELP. IF
BREATHING IS IRREGULAR OR HAS STOPPED, START RESUSCITATION AND
ADMINISTER OXYGEN IF AVAILABLE; SKIN AND EYES: FLUSH WITH PLENTY OF
WATER FOR ABOU T 15 MINUTES. SEEK MEDICAL HELP IF IRRITATION
PERSISTS. INGESTION: DO NOT INDUCE VOMITING. IMMEDIATELY CALL A
PHYSICIAN.
Fire Fighting
Flash Point:NONE
Lower Limits:7.5
Upper Limits:15.0
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE, WATER SPRAY OR
FOG.
Fire Fighting Procedures:USE AIR SUPPLIED BREATHING EQUIPMENT FOR
ENCLOSED AREA.COOL EXPOSED CONTAINERS WITH WATER SPRAY. AVOID
BREATHING VAPOR OR FUMES.
Unusual Fire/Explosion Hazard:CONTAINERS MAY BURST/EXPLODE IN HEAT OF
FIRE.
Accidental Release
Spill Release Procedures:USE PROPER PERSONAL PROTECTION: REMOVE ALL
IGNITION SOURCES: RECOVER FREE LIQUID; USE SUITABLE INERT ABSORBENT
MATERIAL SUCH AS SAND, SAWDUST, ETC.. TO ABSORB SPILLED LIQUID.
VENTILATE CONFINED SPACES .KEEP MATERIAL OUT OF SEWERS AND WATER
COURSES.
Handling
Handling and Storage Precautions:STORE IN A COOL DRY PLACE BELOW 120F.
DO NOT PUNCTURE OR INCINERATE AEROSOL CANS. DO NOT STORE OR HANDLE
NEAR HEAT, SPARKS OR OXIDANTS.
Other Precautions:DO NOT PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL,
GRIND,OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS OR OTHER
SOURCES OF IGNITION:THEY MAY EXPLODE AND CAUSE INJURY OR DEATH.DO
NOT ATTEMPT TO CLE AN SINCE RESIDUE IS DIFFICULT TO REMOVE.
Exposure Controls
Respiratory Protection:USE SUPPLIED-AIR RESPIRATOR PROTECTION IN
CONFINED AREA, IF NEEDED.
Ventilation:PROVIDE >60FPM HOOD FACE VELOCITY. LOCAL EXHAUST TO
MAINTAIN PEL/TLV (USE EXPLOSION PROOF EQUIPMENT.)
Protective Gloves:USE CHEMICAL RESISTANT OTHER THAN RUBBER
Eye Protection:FACE SHIELD/SPLASH PROOF GOGGLES.
Other Protective Equipment:USE CHEMICAL RESISTANT APRON OR OTHER
IMPERVIOUS CLOTHING, IF NEEDED, TO AVOID CONTAMINATING REGULAR
CLOTHING.
Work Hygienic Practices:WASH THOROUGHLY AFTER EACH USE.
Supplemental Safety and Health
AG-RH CLEANER IS CLASS 1 REMOVER OF MIL-I-25135. PER MFRG, PROPELLANT
HAS BEEN SWITCHED FROM CARBON DIOXIDE TO FREON 22 EFFECTIVE MARCH
90. PER MIL-I-25135,REV E AND QPL-25135-14/15,THIS REMOVER,AG-RH
,IS QUALIFIED WITH FORM-D DEVELOPER ANDTYPE II,METH C PENETRANT.
SEE PNIND C FOR OLD CLEANER DATA. KEY1:J7
Chemical Properties
HCC:V2
Vapor Pres:100MMHG@20
Vapor Density:4.55
Spec Gravity:1.32 (BULK)
Evaporation Rate & Reference:1.33 (WATER=1) (BULK)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS LIQUID; SWEET ODOR
Percent Volatiles by Volume:>99%
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENT, STRONG CAUSTICS, REACTIVE METALS LIKE ALUMINUM.
Stability Condition to Avoid:EXTREME HEAT
Hazardous Decomposition Products:HYDROGEN CHLORIDE, SMALL AMOUNT OF
PHOSGENE AND CHLORINE.
Disposal
Waste Disposal Methods:DISPOSE OF RECOVERED MATERIAL AT AN APPROVED
DISPOSAL SITE OR FACILITY. CAN BE RECLAIMED AND RECYCLED. ASSURE
CONFORMITY WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL DISPOSAL
REGULATIONS. DO NOT INCIN ERATE EMPTY OR PARTIALLY FILLED
AEROSOLCANS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.